Carrier

2-Ton 14 SEER R410A Heat Pump (208/230 V 1-Phase) With Coastal Coil Coating

SKU:25HCE424CP03
24AAA6_1_highest-res.jpg
This product is obsolete
Carrier

2-Ton 14 SEER R410A Heat Pump (208/230 V 1-Phase) With Coastal Coil Coating

SKU:25HCE424CP03

    Description

    If you live within 10 miles of the seacoast, chances are you know how harsh salt air can be on an outdoor unit. This tough Comfort series model is designed to withstand the rigors of your environment and is backed by one of the best seacoast warranties you'll find for a heat pump.

    Like all Comfort series heat pumps our coastal model is designed simply to be reliable, efficient and affordable. Be sure to pair it with the right, SEER-boosting indoor furnace or fan coil to gain the most efficiency.

    STANDARD FEATURES

    • WeatherShield™ protection featuring ArmorPlate™ coil coating5, 100% paint coverage and WeatherArmorâ„¢protection for superior seacoast-corrosion resistance
    • 14 SEER cooling efficiency
    • 8.2 HSPF heating efficiency
    • Sound: as low as 72 decibels1
    • Filter drier system protection from moisture and contaminants
    • Non-ozone depleting Puron® refrigerant
    • 10-year parts limited warranty2
    • 5-year coastal corrosion parts limited warranty4

    OPTIONAL FEATURES

    • Optional labor warranty available3


    1 Quietest size within each model group during most common cooling operating condition.

    2 To the original owner, when product is used in a residence, a 10-year parts limited warranty upon timely registration of your new equipment. Warranty period is 5 years if not registered within 90 days. Jurisdictions where warranty benefits cannot be conditioned on registration will automatically receive a 10-year parts limited warranty. See warranty certificate for complete details.

    3 Ask your Carrier® dealer for details.

    4 To the original owner, when product is used in an owner-occupied residence, a 5-year seacoast corrosion parts limited warranty. See warranty certificate for complete details.

    5 Epoxy-phenolic coating for superior corrosion resistance.

    EFFICIENCY

    • 14 SEER
    • Up to 12 EER
    • 8.2 HSPF

    PERFORMANCE

    • Good cold weather performance
    • Hybrid Heat® system compatible when paired with select thermostats
    • Sound: as low as 72 decibels1

    TECHNOLOGY

    • Single-stage scroll compressor
    • System protecting high pressure and loss of charge switches
    • Filter drier
    • Recommended controls: Carrier® Côrâ„¢ thermostat

    CAPACITIES

    • 1.5-5 ton

    REQUIREMENTS

    • 208-230 V

    AESTHETICS

    • Heavy-gauge, galvanized steel construction
    • Baked-on, durable powder coat paint with 100% coverage
    • Dense-wire coil guard


    1 Quietest size within each model group during most common operating condition.

    Specifications

    • BrandCarrier
    • CFM3165.0
    • CoastalTrue
    • Compressor Stage1
    • ConfigurationVertical
    • Cooling Capacity22200
    • Line Voltage (60Hz)240V
    • Nominal Seer14
    • RefrigerantR410A
    • Suction Line Size5/8"
    • Tonnage2
    • Voltage (Phase)208/230 V 1-Phase
    • CFM Nominal3165
    • Coil Guard TypeGrill
    • CompressorScroll
    • Compressor RLA10.9
    • Compressor TypeScroll
    • Condenser Motor HP1/5
    • Condenser Motor RPM1100 rpm
    • Condenser Motor Speeds1 - Speed
    • Condenser Motor TypePermanent Split Capacitor
    • EER11.0, 12.5
    • Fan Diameter24
    • Frequency60
    • Full Load1.1 amp
    • Heating Capacity12700.0, 22000.0
    • Height43.00 in
    • High PressureFalse
    • High Pressure SwitchFalse
    • HSPF8.5
    • InverterFalse
    • LEED CertifiedFalse
    • Length33.50 in
    • Liquid Line FittingSweat
    • Liquid Line Size3/8
    • Liquid Line Size3/8 in
    • Locked Rotor62.9 amp
    • Low PressureTrue
    • Low Pressure SwitchTrue
    • LRA62.9
    • Max Sound Level75
    • Maximum Circuit Breaker25
    • Maximum COP3.74
    • Maximum EER12.5
    • Maximum Heating Capacity22000
    • Maximum Piping Length250
    • Maximum SEER15.5
    • Maximum Voltage253
    • MCA15
    • Metering DeviceTXV
    • Metering Device HeatingPiston
    • Minimum Cooling Capacity20800
    • Minimum EER11
    • Minimum Heat Efficiency HSPF8.2
    • Minimum Heating Ambient Temperature-20
    • Minimum Heating Capacity12700
    • Minimum SEER14
    • Minimum Voltage197
    • Motor PhaseSingle
    • Number Of Fan Blades2
    • Outdoor Fan Motor FLA1.1
    • Outdoor FPI20
    • Outdoor Number of Rows1
    • Package Quantity1 ea
    • Rated Load10.9 amp
    • Rows1
    • SEER14
    • Shipping Height43 in
    • Shipping Length33.5 in
    • Shipping Point38017
    • Shipping Weight180 lb
    • Shipping Width33.5 in
    • Sound BlanketFalse
    • Sound BlanketFalse
    • Sound Level75 dBA
    • Suction Line FittingSweat in
    • Suction Line Size5/8
    • UL ListedTrue
    • UL RecognizedFalse
    • Voltage208/230
    • Weight180 lb
    • Width33.50 in