    Description

    25TPA724A003
    25T = Performance Series Heat Pump Two Stage
    P = Performance
    A = Initial
    7 = 17 SEER2
    24 = 24,000 Btuh
    A = Standard HP
    0 = Not Defined
    0 = Not Defined
    3 = 208/230 ---1

    Specifications

    • BrandCarrier
    • BrandCarrier
    • CoastalFalse
    • Compressor Stage2
    • ConfigurationVertical
    • Cooling Capacity24200
    • FamilyPerformance
    • Line Voltage (60Hz)240V
    • Nominal Seer17
    • RefrigerantR410A
    • Tonnage2
    • Voltage (Phase)208/230 V 1-Phase
    • CFM Cooling650
    • CFM Heating3158
    • CFM Nominal840
    • Coil Guard TypeLouver
    • CompressorScroll
    • Compressor RLA10.9
    • Compressor TypeScroll
    • Condenser Motor HP0.08
    • Condenser Motor RPM800 rpm
    • Condenser Motor Speeds1 - Speed
    • Condenser Motor TypePropeller Type, Direct Drive
    • Frequency60
    • Height35 1/2" in
    • High PressureFalse
    • High Pressure SwitchFalse
    • HSPF9.5
    • InverterFalse
    • LEED CertifiedFalse
    • Length35" in
    • Liquid Line FittingSweat
    • Liquid Line Size3/8
    • Low PressureFalse
    • Low Pressure SwitchFalse
    • LRA61
    • Max Sound Level73
    • Maximum Circuit Breaker25
    • Maximum EER14
    • Maximum Heating Capacity24400
    • Maximum Piping Length250
    • Maximum SEER18.5
    • Maximum Voltage253
    • MCA17
    • Metering DeviceTXV/TXV
    • Metering Device HeatingTXV
    • Min Sound Level71
    • Minimum Cooling Capacity22600
    • Minimum EER11
    • Minimum Heat Efficiency HSPF8.8
    • Minimum Heating Ambient Temperature-20
    • Minimum Heating Capacity13300
    • Minimum SEER15
    • Minimum Voltage197
    • Motor Phase1
    • Number Of Fan Blades3
    • Outdoor Coil MaterialTube
    • Outdoor Fan Motor FLA0.5
    • Outdoor FPI20
    • Outdoor Number of Rows2
    • SEER18
    • Shipping Height40.75 in
    • Shipping Length38 in
    • Shipping Weight255 lb
    • Shipping Width38 in
    • Sound BlanketFalse
    • Sound BlanketFalse
    • Suction Line FittingSweat in
    • Suction Line Size3/4
    • UL ListedFalse
    • UL RecognizedFalse
    • Voltage208/230-1
    • Weight227 lb
    • Width35" in

    Equipment Parts List