This product has been superseded by
SKU:25HCE418A003
This product has been superseded by
SKU:25HCE418A003Description
25HCE418A003
25H = Comfort Series Heat Pump with Puron Refrigerant
C = Comfort
E = Puron
4 = 14 SEER
18 = 18,000 Btuh
A = Dense Grille
0 = Not Defined
0 = Not Defined
3 = 208/230 ---1
25H = Comfort Series Heat Pump with Puron Refrigerant
C = Comfort
E = Puron
4 = 14 SEER
18 = 18,000 Btuh
A = Dense Grille
0 = Not Defined
0 = Not Defined
3 = 208/230 ---1
Standard Features
- 14 SEER cooling efficiency
- 8.2 HSPF heating efficiency
- Sound: as low as 69 decibels
- Filter drier system protection from moisture and contaminants
- WeatherArmor™ protection
- Non-ozone depleting Puron® refrigerant
- 10-year parts limited warranty1
Optional Features
- Optional labor warranty available
1See warranty certificate for complete details
Specifications
- BrandCarrier
- BrandCarrier
- CFM1700
- CoastalFalse
- Compressor Stage1
- ConfigurationVertical
- Cooling Capacity17700, 18000
- FamilyComfort
- Nominal Seer14
- RefrigerantR410A
- Suction Line Size5/8"
- Tonnage1.5
- Voltage (Phase)208/230 V 1-Phase
- CFM Nominal1700
- Coil Guard TypeGrill
- CompressorScroll
- Compressor RLA9
- Compressor TypeScroll
- Condenser Motor HP1/12
- Condenser Motor RPM1100 rpm
- Condenser Motor Speeds1 - Speed
- Condenser Motor TypePermanent Split Capacitor
- EER11.5, 12.2
- Fan Diameter18
- Frequency60
- Full Load0.5 amp
- Heating Capacity10100, 18000
- Height40.00 in
- High PressureTrue
- High Pressure SwitchTrue
- HSPF8.2
- InverterFalse
- LEED CertifiedFalse
- Length25.25 in
- Liquid Line FittingSweat
- Liquid Line Size3/8
- Liquid Line Size3/8 in
- Locked Rotor48 amp
- Low PressureTrue
- Low Pressure SwitchTrue
- LRA48
- Max Sound Level69
- Maximum Circuit Breaker20
- Maximum COP3.72
- Maximum EER12.2
- Maximum Fuse Size20 amp
- Maximum Heating Capacity18000
- Maximum Piping Length250
- Maximum SEER14.5
- Maximum Voltage253
- MCA12
- Metering DeviceTXV
- Metering Device HeatingPiston
- Minimum Ambient Temperature-20 °F
- Minimum Cooling Capacity17700
- Minimum EER11.5
- Minimum Heat Efficiency HSPF8.2
- Minimum Heating Ambient Temperature-20
- Minimum Heating Capacity10100
- Minimum SEER14
- Minimum Voltage197
- Motor Phase1
- Number Of Fan Blades2
- Outdoor Fan Motor FLA0.5
- Outdoor FPI25
- Package Quantity1 ea
- Rated Load9 amp
- Rows1
- SEER14
- Shipping Height40 in
- Shipping Length25.25 in
- Shipping Point38017, 38611
- Shipping Weight166 lb
- Shipping Width25.25 in
- Sound BlanketFalse
- Sound BlanketFalse
- Sound Level69 dBA
- Suction Line FittingSweat in
- Suction Line Size5/8
- UL ListedTrue
- UL RecognizedTrue
- Voltage208/230
- Weight136 lb
- Width25.25 in
Equipment Parts List