Description
FY5BNF024L00
F = Fan Coil
Y = RNC (R-410A)
5 = Upflow/Downflow
B = Second Series
N = 208/230-1-60
F = Single piece Cabinet
024 = 24,000 Btu
L = Aluminum Coil
00 = No Heating
F = Fan Coil
Y = RNC (R-410A)
5 = Upflow/Downflow
B = Second Series
N = 208/230-1-60
F = Single piece Cabinet
024 = 24,000 Btu
L = Aluminum Coil
00 = No Heating
Standard Features
- All aluminium coils for enhanced corrosion resistance
- Standard-efficiency, fixed-speed blower motor
- Multi-flow piston metering device (TXV in 5 ton size only)
- Sloped, corrosion-free drain pan design helps reduce mold and bacteria build-up
- Non-ozone depleting Puron® refrigerant
- Fully insulated cabinet
- 10-year parts limited warranty1
Optional Features
- Can be purchased with a factory-installed or optional, field-installed, electrical-resistance heating package
- Optional labor warranty available
Specifications
- BrandCarrier
- CFM800
- ConfigurationVertical
- Cooling Capacity24000
- Line Voltage (60Hz)240V
- RefrigerantR410A
- Supply Plenum Width17"
- Tonnage2
- Condenser Motor HP1/4
- Height49.63 in
- Length22.06 in
- Motor Phase1
- Package Quantity1 ea
- Rows3
- Shipping Weight128 lb
- UL ListedTrue
- UL RecognizedTrue
- Voltage208/230-1
- Weight120 lb
- Width17.63 in
Equipment Parts List