This product is obsolete
Weathermaker

3-Ton 16 SEER R410A 2-Stage Heat Pump (208/230 V 1-Phase)

SKU:PH16NA03600G
PH16NA_1_highest-res.jpg
This product is obsolete
Weathermaker

3-Ton 16 SEER R410A 2-Stage Heat Pump (208/230 V 1-Phase)

SKU:PH16NA03600G

    Description

    PH16NA03600G
    PH16 = 16 SEER Heat Pump
    N = 208/230 ---60 ---1
    A = Puron
    036 = 36,000 Btuh
    00G = Dense Grille

    Standard Features

    • Quiet performance (as low as 71 decibels)1
    • Two-stage compressor for improved temperature and summer humidity control
    • Durably built with tight wire grille to withstand bad weather and debris
    • Designed for corrosion resistance and lasting performance
    • 10-Year Parts Limited Warranty*

    Specifications

    • BrandWeathermaker
    • BrandWeathermaker
    • CFM3200
    • CoastalFalse
    • Compressor Stage2
    • ConfigurationVertical
    • Cooling Capacity34000, 36400
    • Line Voltage (60Hz)240V
    • Nominal Seer16
    • RefrigerantR410A
    • Suction Line Size7/8"
    • Tonnage3
    • Voltage (Phase)208/230 V 1-Phase
    • Air FlowVertical
    • CFM Nominal3200
    • Coil Guard TypeGrill
    • CompressorScroll
    • Compressor RLA18.5
    • Compressor TypeScroll
    • Condenser Motor HP1/12
    • Condenser Motor RPM800 rpm
    • Condenser Motor Speeds2 - Speed
    • Condenser Motor TypePSC
    • EER13.3
    • Frequency60
    • Full Load0.6 amp
    • Heating Capacity21800, 36600
    • Height32.06 in
    • High PressureTrue
    • High Pressure SwitchTrue
    • HSPF9.5
    • InverterFalse
    • LEED CertifiedFalse
    • Length35 in
    • Liquid Line FittingSweat
    • Liquid Line Size3/8
    • Liquid Line Size3/8 in
    • Locked Rotor83 amp
    • Low PressureTrue
    • Low Pressure SwitchTrue
    • LRA83
    • Max Sound Level74
    • Maximum Circuit Breaker35
    • Maximum COP4.06
    • Maximum EER13.3
    • Maximum Fuse Size40 amp
    • Maximum Heating Capacity35400
    • Maximum Piping Length250 Ft.
    • Maximum SEER17
    • Maximum Voltage253
    • MCA24
    • Metering DeviceTXV
    • Metering Device HeatingPiston
    • Minimum Ambient Temperature55° F °F
    • Minimum Cooling Capacity34000
    • Minimum EER13.3
    • Minimum Heat Efficiency HSPF8.2
    • Minimum Heating Ambient Temperature55
    • Minimum Heating Capacity21800
    • Minimum SEER14
    • Minimum Voltage197
    • Motor Phase1
    • Number Of Fan Blades3
    • Outdoor Fan Motor FLA0.5
    • Outdoor FPI20
    • Package Quantity1 ea
    • Rated Load18.5 amp
    • SEER17
    • Shipping Height33.75 in
    • Shipping Length36 in
    • Shipping Point38017
    • Shipping Weight237 lb
    • Shipping Width36 in
    • Sound BlanketFalse
    • Sound BlanketTrue
    • Sound Level74 dBA
    • Suction Line FittingSweat in
    • Suction Line Size7/8
    • UL ListedTrue
    • UL RecognizedTrue
    • Voltage208/230
    • Weight215 lb
    • Width35 in

    Equipment Parts List