HomeHome
HomeHome
HomeHome
HomeHome
Emerson

Emerson True, 2H/2C, 4H/2C Thermostat

SKU:1F95-0680
1F95-0680_001.jpg
Emerson

Emerson True, 2H/2C, 4H/2C Thermostat

SKU:1F95-0680

    Description

    Emerson Electric Co. (White-Rodgers) Blue™ 30 VAC, 32 to 105 Deg F, Horizontal Cover, Digital, Universal, 7/5-1-1 Day Programmable/Non-Programmable, 1-Heat/1-Cool 1-Stage, 2-Heat/2-Cool Multi-Stage, 4-Heat/2-Cool Heat Pump, Thermostat

    Features & Benefits

    • Easy Reader Model is Easy to Read and Easy to Use
    • Commercial Offers Occupied Damper or Economizer Control and Locking Cover and Subbase
    • Staging Control for Nearly All Conventional and Heat Pump Systems
    • 1-Stage Model Compatible with All Single Stage Systems Low Voltage, 750 Millivolt and 3-Wire Zone Systems
    • Heat Pump Dual Fuel Option Eliminates the Need for a Fossil Fuel Kit
    • Indoor Remote Sensor for Averaging Option
    • Outdoor Remote Sensor Option on Select Universal Models for outdoor Temperature Reading and Dual Fuel Balance Point or Outdoor Thermostat Function
    • Dual Power Hardwire and/or Battery or Tri-Power - Hardwire and/or Battery with System Assist

    Specifications

    • Type: Digital, Universal, 7/5-1-1 Day Programmable/Non-Programmable, 1-Heat/1-Cool 1-Stage, 2-Heat/2-Cool Multi-Stage, 4-Heat/2-Cool Heat Pump
    • Cover Type: Horizontal
    • Voltage Rating: 30 Volt AC (Battery Powered), 24 Volt AC 50/60 Hertz (Hardwired)
    • Current Rating: 1.5 to 2.5 Amp (Load Terminal)
    • Temperature Rating: 32 to 105 Deg F
    • Size: 6.4 Inch Width x 1.7 Inch Depth x 4.2 Inch Height
    • Display Size 6 Square Inch
    • Terminal Designation RC, RH, C, W/E, W2, Y, Y2, O/B, G, 6, L, +, S, -, A1
    • Set Point Temperature Rating 45 to 99 Deg F
    • Humidity Rating 90 Percent (Non-Condensing)
    • Inclusion/Feature Economizer Connection, Key Press or Continuous with Common Wire Backlight, Heat Pump Dual Fuel Control, Auto Changeover, Filter Change Reminder, Energy Mounting Recovery/Early Start, Setpoint Temperature Limit, Lighted Display, Cool Saving
    • Application Gas/Oil/Electric, 3-Wire Zone Valve, Millivolt System
    • Applicable Standard NEC Class II

    Documents

    There are no documents available.

    Specifications

    • BrandEmerson
    • Built In Wi-FiFalse
    • Digital ProgrammableTrue
    • Power MethodBattery Or Hardwired
    • Stages2H/2C, 4H/2C
    • Support Capacitive TouchFalse
    • Amps2.5
    • ApplicationHeat/Cool, Heat Pump
    • BacklitTrue
    • DisplayLCD
    • Height1.875 in
    • Length4.1875 in
    • Parts ApplicationHP W/Aux
    • Shipping Height1.875 in
    • Shipping Length4.1875 in
    • Shipping Width6.5 in
    • Temperature Range45 To 99
    • UL ListedFalse
    • UL RecognizedFalse
    • Voltage24