24,000 BTU 21 SEER 2-Zone Heat Pump System 9+12 - Ducted

33D4790D-C94F-4B84-A364-5F72A07296FE
Outdoor Unit Model:
24K Outdoor Ductless HP Multi Zone Performance 208/230V R410A
Zone 1 Indoor Model:
9K Ducted Ductless Indoor HP Performance 208/230V R410A
Zone 2 Indoor Model:
12K Ducted Ductless Indoor HP Performance 208/230V R410A
  • SKU 33D4790D-C94F-4B84-A364-5F72A07296FE
  • SKU Key 33D4790D-C94F-4B84-A364-5F72A07296FE
  • Title 24,000 BTU 21 SEER 2-Zone Heat Pump System 9+12 - Ducted
  • Description <p>This Carrier 2 Ton MGR Series ductless inverter driven multi-zone system includes the outdoor heat pump and (2) Ducted indoor units.</p><p>The outdoor unit can have a maximum of 3 zones. So you can add and additional 1 zones in the future as long as you remain within the recommended sizing guidelines</p>The system combination is Energy Star rated and has a combined system efficiency of 21 SEER, 11 EER, and 10 HSPF. The AHRI number for this combination is 204707613<br><br><p><b>Recommended Wiring:</b> The main power is supplied to the outdoor unit. The field supplied 14/3 stranded wire with ground with a 600 volt insulation rating, power/communication wiring from the outdoor unit to indoor unit consists of four (4) wires and provides the power for the indoor unit. Two wires are line voltage AC power, one is communication wiring (S) and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended.</p><b>Recommended Piping:</b><br><b>Zone 1 40MBDQ09---3: </b>3/8" Vapor Line - 1/4" Liquid Line <br><b>Zone 2 40MBDQ12---3: </b>1/2" Vapor Line - 1/4" Liquid Line <br><br><p>Some of the benefits of the Carrier MGR Series multi-zone system include:</p><p><b>Fast Installation:</b> This compact ductless system is simple to install. A mounting bracket is included with the indoor units and only wires and piping need to run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in homes or the workplace. This makes the 38MGR systems the equipment of choice for retrofit applications.</p><p><b>Simple Servicing and Maintenance:</b> Removing the top panel of the outdoor unit provides immediate access to the control compartment, providing the service technician access to the diagnostic LEDs to facilitate the troubleshooting process. In addition, the draw−thru design of the outdoor unit means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.</p><p>On the indoor units, service and maintenance expense is reduced due to the permanent easy to clean filters. Also, error codes are displayed on the front panel to alert the user to certain system malfunctions</p><p><b>Built−in Reliability:</b> Ductless system indoor and outdoor units are designed to provide years of trouble−free operation. </p><p>Both the indoor and outdoor units are well protected. Whenever the microprocessor detects abnormal conditions, the unit stops and an error code appears. </p><p><b>Easy−To−Use Controls:</b> The multi−zone systems have microprocessor−based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote controls provide the interface between the user and the unit.</p>
  • Enrichment Status Final
  • Enrichment Score 100
  • Enrichment Level Rank A+ (Fully Enriched including optional fields)
  • Dummy kit image 6-10-22
  • Special Order No
  • SKU 33D4790D-C94F-4B84-A364-5F72A07296FE
  • SKU Key 33D4790D-C94F-4B84-A364-5F72A07296FE
  • Enrichment Score 100
  • Enrichment Level Rank A+ (Fully Enriched including optional fields)
  • Dummy 4-22-21 Dummy
  • Additional Refrigerant Required (Oz/Ft) 0.16 Oz/Ft
  • AHRI # 204707613
  • Brand Carrier
  • Cooling Capacity Range (btus) 7650~30400
  • Cooling Operating Range ° F (° C) -13~122 (-25~50)
  • COP (5F) 2
  • COP (47F) 3.8
  • Number of Zones 2
  • EER 11
  • Energy Star Rated Yes
  • Heating Capacity Range (btus) 5950~36200
  • Heating Operating Range ° F (° C) -22~86 (-30~30)
  • HSPF 10
  • Indoor Configuration 9+12
  • Indoor Style Ducted
  • Max Piping Drop 45
  • Max Piping Length Per Zone (Ft) 98
  • Max Piping Lift 45
  • MCA 25
  • Min Piping Length Per Zone (Ft) 10
  • MOCP Fuse Rating 35
  • Outdoor Tonnage 2
  • Outdoor Unit Voltage 208/230V
  • Pre-Charge Piping Length (Ft) 74
  • Refrigerant R410A
  • Refrigerant Charge Amount (Lbs) 6.17
  • SEER 21
  • Total Piping Length (Ft) 197
  • Zone 1 Cooling 9500
  • Zone 1 Heating 10000
  • Zone 2 Cooling 12000
  • Zone 2 Heating 13000

This Carrier 2 Ton MGR Series ductless inverter driven multi-zone system includes the outdoor heat pump and (2) Ducted indoor units.

The outdoor unit can have a maximum of 3 zones. So you can add and additional 1 zones in the future as long as you remain within the recommended sizing guidelines

The system combination is Energy Star rated and has a combined system efficiency of 21 SEER, 11 EER, and 10 HSPF. The AHRI number for this combination is 204707613

Recommended Wiring: The main power is supplied to the outdoor unit. The field supplied 14/3 stranded wire with ground with a 600 volt insulation rating, power/communication wiring from the outdoor unit to indoor unit consists of four (4) wires and provides the power for the indoor unit. Two wires are line voltage AC power, one is communication wiring (S) and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended.

Recommended Piping:
Zone 1 40MBDQ09---3: 3/8" Vapor Line - 1/4" Liquid Line
Zone 2 40MBDQ12---3: 1/2" Vapor Line - 1/4" Liquid Line

Some of the benefits of the Carrier MGR Series multi-zone system include:

Fast Installation: This compact ductless system is simple to install. A mounting bracket is included with the indoor units and only wires and piping need to run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in homes or the workplace. This makes the 38MGR systems the equipment of choice for retrofit applications.

Simple Servicing and Maintenance: Removing the top panel of the outdoor unit provides immediate access to the control compartment, providing the service technician access to the diagnostic LEDs to facilitate the troubleshooting process. In addition, the draw−thru design of the outdoor unit means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.

On the indoor units, service and maintenance expense is reduced due to the permanent easy to clean filters. Also, error codes are displayed on the front panel to alert the user to certain system malfunctions

Built−in Reliability: Ductless system indoor and outdoor units are designed to provide years of trouble−free operation.

Both the indoor and outdoor units are well protected. Whenever the microprocessor detects abnormal conditions, the unit stops and an error code appears.

Easy−To−Use Controls: The multi−zone systems have microprocessor−based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote controls provide the interface between the user and the unit.

QTY